tousek
/ E_ST61_07 / 06. 06. 2019
- 21 -
Dropbolt control unit
DROPBOLT 1
DROPBOLT 2
motor print 2
pre-wired
motor print 1
pre-wired
dropbolt
module
(to install in the
swing gate control unit)
3 4 4 3 1
2
M– M+
L N
5 6
Y/+ Y/-
Y/1
Y/2
Y/3Y/4Y/5
X/+ X/-
X/1
X/2
X/3X/4X/5
230V
a.c.
L N
Trafo1
primary
Trafo1
second.
3 4 4 3 1
2
M– M+
L N
5 6
230V
a.c.
L N
Trafo2
primary
Trafo2
second.
3 4
2 1
3 4
2 1
3
4
2
1
cable 4x0,75
2
3
4
2
1
cable 4x0,75
2
Limit switch closed,
if the bolt is retracted
motor
connection
Limit switch closed,
if the bolt is retracted
„X“-block“
„Y“-block
motor
connection
Wire the terminal block
(K)
of the dropbolt´s printed circuit board as shown on the picture::
• on one hand wire it with the module, which is connected to the operator´s control unit:
- for 1 dropbolt: wire only with the terminal block „X“ - for 2 dropbolts wire with terminal blocks „X“+“Y“
• on the other hand wire it with the dropbolt via connection cable 4 x 0,75
2
(motor connection and limit switch) .
Strictly note the numbering
1 – 4
of the connection cable´s wires for a proper connection.
• Carry out the 230V a.c. power supply connection on terminal block
(V)
and the earthing connection on the earthing
screw.
SAFELOCK-control unit with 2 motor prints:
• suitable for 2 dropbolts
• connection motor print 1: with „X“-terminal block
• connection motor print 2: with „Y“-terminal block
T1
T2
N
L
supply
230V
a.c.
V
motor print 2
P
F1
F2
K
J
motor print 1
P
F1
F2
K
J
SAFELOCK-control unit with 1 motor print:
• suitable for 1 dropbolt
• connection motor print: with „X“-terminal block
T1
N
L
supply
230V
a.c.
V
motor print 1
P
F1
F2
K
J
(P)
programming slot
(F1)
fuse 0,25A T
(F2)
fuse 4A T
(J)
Jumper
(T1)
transformer 1
(T2)
transformer 2
(K)
terminals
(V)
230Va.c. supply terminals
Jumper
J
motor print
T
„T“
with tousek
control units ST 51,
ST 61, ST REX
T
„ “
with foreign
control units