- 16 -
tousek
/ E_ST61_07 / 06. 06. 2019
Right leaf
Connections and adjustments
G
Motor
(Supply: terminals 24/25/26, grounding: 27 - Sensor: terminals 65, 67, 68)
Right leaf
MOTOR ON
MOTOR OFF
.
left motor
right motor
INSIDE
If a right operator is not available then
set here to „MOTOR OFF“!
G
Delay right leaf
Right leaf
OPENING DELAY:
the right leaf opens after the adjusted delay time.
CLOSING DELAY:
the right leaf closes after the adjusted delay time.
G
Delay time right
2s (factory setting)
Right leaf
0–25s time delay adjustable:
indicates the delay time at opening or closing.
ARS response time
0,50 (factory setting)
Right leaf
0,15–0,95 adjustable:
indicates the response of the Automatic Rerversal System.
Max. force
70% (factory setting)
Right leaf
20–100% adjustable:
indicates the motor force in opening/closing movement.
Soft stop time
5s (factory setting)
Right leaf
0–25s adjustable:
indicates the duration of the soft stop time.
Soft start
Right leaf
not active
active:
soft start with SWING X.
The option „soft start“ is only inserted for
SWING X. With SPIN operator soft start is
always active!
Impulse logic
Operating logic
stop, start of pause time:
a command of the impulse switch during the opening movement stops the gate and starts
the pause time in automatic operation – as soon as the pause time has run out, the gate closes automatically.
impulse suppression when opening:
commands which are emitted during the opening movement are suppressed.
Commands during closing are accepted.
pause time extension:
an impulse in automatic operation restarts the pause time. If this menu point is chosen, the
impulse suppression during opening is active at the same time.
Operating mode
Connections and adjustments
Left leaf
Connections and adjustments
G
Motor
(Supply: terminals 20/21/22, grounding: 23 - Sensor: terminals 65, 66, 68)
Left leaf
MOTOR ON
MOTOR OFF
.
left motor
right motor
INSIDE
If a left operator is not available then set
here to „MOTOR OFF“!
G
Delay left leaf
Left leaf
OPENING DELAY:
the left leaf opens after the adjusted delay time.
CLOSING DELAY:
the left leaf closes after the adjusted delay time.
G
Delay time left
2s (factory setting)
Left leaf
0–25s time delay adjustable:
indicates the delay time at opening or closing.
ARS response time
0,50 (factory setting)
Left leaf
0,15–0,95 adjustable:
indicates the response of the Automatic Rerversal System.
Max. force
70% (factory setting)
Left leaf
20–100% adjustable:
indicates the motor force in opening/closing movement.
Soft stop time
5s (factory setting)
Left leaf
0–25s adjustable:
indicates the duration of the soft stop time.
Soft start
Left leaf
not active
active:
soft start with SWING X.
The option „soft start“ is only inserted for
SWING X. With SPIN operator soft start is
always active!