Push buttons, key switches or external radio receivers with potential-free contacts can be used as impulse
switches.
• For some menu points e.g. stop-button, photocells and safety sensing edges, the status of the according input as well as
the terminal numbers are shown on the text display.
• A general status display of all inputs is available in menu DIAGNOSIS/STATUS DISPLAY.
The single menu points are marked as shown below:
= possible adjustment (or value assignment)
= factory setting
= status display
G
marks the menu points which are contained in the BASIC SETTINGS
G
Impulse button
(terminals 30/32)
Buttons/switches
OPEN/STOP/CLOSE successive impulses (factory setting):
an impulse of the impulse switch makes the motor start
opening/closing. If the impulse switch is actuated again during this opening-/closing movement, the motor stops. With the
next command of the impulse switch the motor moves in the opposite direction of the last gate movement
OPEN/CLOSE/OPEN successive impulses:
an impulse of the impulse switch makes the motor start opening/clos-
ing. If the impulse switch is actuated again during this opening/closing movement, the travel direction is reversed.
•
In this operation mode it is not possible to stop the motor with the impulse switch – it always
moves until reaching an end position. (Opened or closed position).
• for the function OPEN/CLOSE/OPEN we strongly suggest the installation of a photocell!
OPEN:
Only opening commands are accepted by the impulse switch – closing the gate with the impulse switch is not
possible.
DEAD MAN:
The motor opens as long as the impulse switch is pressed (hold) – closing the gate with the impulse
switch is not possible. As soon as the switch is released, the motor stops.
If hold to run operating mode is selected,
the radio receiver slot (FE) is set out of order for reasons of safety.
• If the impulse switch is set to DEAD MAN operation, then the pedestrian button works the same way.
With the impulse switch or the pedestrian button the gate is opened, with the CLOSE-button it is closed.
• IMPORTANT: Do not put into operation in dead man mode.
Select only after putting into operation
(
page 24)
, if desired.
Buttons/switches
Connections and adjustments
4. Connections and adjustments
Swing gate control unit ST 61
Warning
•
Before taking off the control cover, the
mains switch must be turned off!
•
If the control is power supplied, its inner part is under
tension.
•
In order to avoid electrical strokes, the safety regula-
tions have to be kept.
•
The device may only be connected by trained profes-
sionals.
•
The product is not suitable for installation in explosion-
hazardous areas.
•
An all-pole disconnecting mains switch with a contact
opening gap of min. 3 mm has to be foreseen. The
gate facility has to be secured according to the valid
safety regulations!
•
IMPORTANT: The control lines (sensor, buttons, radio,
photocells, etc.) have to be laid separately from the
230V lines (supply line, motors, signal lamp).