- 4 -
tousek
/ E_ST61_07 / 06. 06. 2019
FE
–
ESC
ENTER
+
Textdisplay
T
D
F1
ZM
K
B
E
VE
Control board features
1. General information
Swing gate control unit ST 61
• suitable for swing gates with electromechanical operators
SWING X and SPIN 250, 230V (1 or 2 gate leafs) with inte
-
grated sensor.
• leaf delay adjustable at opening and closing
• automatic closure with adjustable pause time
• travel time of both operators will be adjusted automatically
• separately adjustable softstop time of both operators
(no loss of force even with reduced speed).
• Safety system ARS (autom. reversal system)
• operating mode: impulse, automatic or dead man mode
• ntegrated evaluation of safety sensing edges
• self-monitoring of photocells
• self-diagnosis display
• optional module: “electric lock /magnetic clamp” or “motor lock”
• slots for optional and status display module and radio receiver
Components of the control board
(K)
terminal blocks
(D)
display connector
(with programming b, -, ESC, ENTER)
or TC/TSI-connection (optional „tousek-connect“/
„tousek service Interface“)
(E)
System connector for optional module motor lock or
electric lock / magnet (
page 20)
(VE)
230V a.c. for electric lock/magnet module
(B)
system connector
(FE)
slot for optional radio receiver (
page 23)
(ZM)
slot for optional module „status display“
(
page 19)
(T)
transformer
(F1)
fuse 6,3A F
Control board overview
Technical data
Swing gate control unit ST 61
power supply
230V a.c., +/-10% 50Hz
magnetic clamp output
optional 24Vd.c.
motor output
2 x 500W, 230V a.c.
ambient temperature
- 20°C bis + 70°C
flashing light output
230V AC, 40W
protection class
IP54
electric lock output
optional 12Vd.c. oder 24V d.c.
speed sensor
photocell output
24V a.c.
art.number
12111670
optional components
pluggable radio receiver • additional module for courtyard/control lamp • Additional module for
gate status evaluation • E-lock/magnet module • radio transmission system TX 310
Attention
During connection,
adjustment and mainte-
nance works please take
care, that the electronic
circuit board won´t be
damaged by moisture
(rain).
Important
The optional „tousek-
connect“ or the „tousek-
service interface“ must
be connected with
socket
(D)
!