main closing edge 2
(right leaf or outside)
main closing edge 1
(left leaf or inside)
8,2kOhm
8,2kOhm
53
52
50
HSK 2
HSK 1
G
Operating mode
Operating logic
impulse mode:
for initiating the closing movement, an impulse is necessary.
automatic closing, pause time adjustable from 1-255s:
gate closes as soon as the adjusted pause time has run out.
Partial opening
100% (factory setting)
Operating logic
25–100% adjustable:
indicates the partial opening of the gate leaf with closing delay in relation to complete opening
width.
This adjustment is ONLY adopted in CLOSED Postion.
Automatic mode
Operating logic
complete/partial opening:
either with complete as well as partial opening, the gate closes automatically after the
adjusted pause time.
only complete opening:
only after complete opening, the gate closes automatically after the adjusted pause time.
only partial opening:
only after partial opening the gate closes automatically after the the adjusted pause time.
Pause time logic
Operating logic
no influence
permanent open in automatic mode:
if this function is activated, the control unit goes from automatic mode into impulse
mode
with activated pause time through impulse in open gate position
for this cycle , hence if gate is open then an
impulse will end the automatic mode - the gate remains open. Only the next impulse will close the gate and the control unit
goes back to automatic mode. With this function e.g. the entrance to a company site can remain open during the day (1st
impulse in gate open position) and closed in the evening (2nd impulse). The control board switches back to automatic mode
(autom. opening and closing of gate).
If the gate is in partial open position and „permanent open in automatic mode“ is selected, so it is possible to adjust
permanent partial open for this cycle by giving an impulse via
pedestrian button.
Permanent partial open can be
finished analogous to the above described method.
Closing edges
(HSK 1: terminals 50/52, HSK 2: terminals 50/53)
Operating logic
left/right:
the safety sensing edges (contact strips)
can actuate in every gate movement (OPEN/CLOSE) .
The safety sensing edge 1 (terminal 50/52) is mounted
on the left gate wing and the safety sensing edge 2
(terminal 50/53) on the right wing.
inside/outside:
sensing edges at the interior of the gate (terminal 50/52) can only actuate during opening movement
and sensing edges on the outside of the gate (terminal 50/53) only during closing movement.
IMPORTANT !
ASSIGNMENT AND RESPONSE OF SAFETY EDGES
Movement
Assignment
Open
Close
Examples:
(D) passage edge, (E) final edge
left (HSK 1 - Kl.50/52)
right (HSK 2 - Kl.50/53)
D
E
D
E
outside (HSK 2-term.50/53)
D
E
inside (HSK 1-term.50/52)
D
E
HSK 1
Mode
left/right
left
active
active
HSK 2
right
active
active
HSK 1
Mode
inside/outside
inside
active
HSK 2
outside
active
Limit tolerance
20 (factory setting)
Operating logic
3–20 adjustable:
indicates the tolerance in the end positions (low value = sensitive behaviour).