58
59
Reference
Troubleshooting
Warm Air Drying
Trouble
y g
Please check
Ref.
Page
The dryer temperature
is low.
Page
Is the remote control preset temperature set to a low level?
●
22
Stops in the middle of
use.
Does the seat switch have diffi culty detecting?
●
Sit back on the toilet seat. If you get up slightly from the seat, or sit forward
➞
on the seat, the seating switch may temporarily stop detecting your
presence.
11
Toilet Seat and Toilet Lid (AUTO OPEN/CLOSE)
Trouble
(
)
Please check
Ref.
Page
The toilet lid does not
open automatically.
Page
Is "AUTO OPEN/CLOSE" set to "OFF"?
●
➞
Set to "ON".
Even when set to "
●
ON", AUTO OPEN/CLOSE is not performed for about 15 seconds
after the toilet seat or toilet lid is closed.
When the toilet lid is closed by hand
x
(To make the Washlet more user-friendly, a time interval is set from when the lid
is closed to when it will open next.)
Move away from the toilet and wait at least 15 seconds before approaching
➞
the bowl unit again.
Detection by the body sensor may be diffi cult when the room temperature
●
exceeds 86°F (30°C).
Open and close with the remote control.
➞
42
–
19
–
Open and close with the remote control.
➞
Did you set the time until the next lid opening to 30 seconds or 90 seconds?
●
44
y
p
g
[North, Central, South America]
After the power plug is inserted, the toilet lid does not open automatically for
●
about 10 to 60 seconds.
Open and close with the remote control.
➞
[Asia, Oceania, Middle East]
After the distribution board breaker is switched to ON, the toilet lid does not
●
open automatically for about 10 to 60 seconds.
Open and close with the remote control.
➞
14
Open and close with the remote control.
➞
●
Is a toilet lid or seat cover installed?
➞
Remove any covers.
–
The toilet lid does not
close automatically.
y
Is "AUTO OPEN/CLOSE" set to "OFF"?
●
➞
Set to "ON".
When the time spent sitting on or standing in front of the toilet seat is less
●
than 6 seconds, the toilet seat and toilet lid will close after about 5 minutes.
If they do not close automatically even though "AUTO OPEN/CLOSE" is set
●
to "ON", the body sensor may be detecting incorrectly.
If there is a reflective object in front, such as a mirror or glass, move the
➞
reflective object or use a curtain or other object to block it.
42
–
11
The toilet lid opens
on its own.
reflective object or use a curtain or other object to block it.
Is the sensor directly exposed to sunlight?
●
Do not directly expose the sensor to sunlight, because it may cause
➞
incorrect detection.
Is there a heater within the detection range of the body sensor?
●
Do not place within the detection range of the sensor.
➞
Is a urinal or wash basin also installed in the bathroom?
●
The sensor may detect someone using the urinal, causing the toilet lid to open or
➞
close.
11
Toilet Seat and Toilet Lid (AUTO OPEN/CLOSE)
Trouble
(
)
Please check
Ref.
Page
The toilet lid closes
on its own.
Page
Is "AUTO OPEN/CLOSE" set to "ON"?
●
Is AUTO CLOSE WAITING TIME set to 25SEC?
●
The seat sensor may have diffi culty detecting some sitting postures.
●
Sit back on the toilet seat.
➞
42
11
The toilet lid and toilet
seat open at the same
time.
Sit back on the toilet seat.
Are the settings confi gured to open the toilet lid and toilet seat at the same
●
time?
44
time.
Stops (or closes)
while opening.
[North, Central, South America]
If the lid or seat hits an obstruction the fi rst time it opens after inserting the
●
power plug, it may stop (or close) partway during the next operation.
While there are no obstructions, disconnect the plug and insert it again
➞
after about 5 seconds. Then press the "SEAT OPEN/CLOSE" button on the
remote control.
[Asia, Oceania, Middle East]
If the lid or seat hits an obstruction the fi rst time it opens after the breaker on
●
the distribution board is switched ON, it may stop (or close) part way through
the next operation.
Eliminate any obstructions and switch the breaker on the distribution
➞
board to OFF. Switch it to ON again after about 5 seconds. Then press the
"OPEN/CLOSE" button on the remote control.
17
The open timing has
changed.
OPEN/CLOSE button on the remote control.
Detection by the
●
body sensor may be diffi cult when the room temperature
exceeds 86°F (30°C), such as in the summertime.
11
Summary of Contents for NEOREST