54
55
Reference
Troubleshooting
First, try the actions described on pages 56 to 61. If the problem persists, consult
the installer, seller or the contact listed on the back cover of this manual.
If the CLEAN indicator no longer lights up...
Consult with the contact referred on the back cover of this manual.
If all LEDs are
À
ickering:
Consult with the contact referred on the back cover of this manual.
CAUTION
If a water leak occurs,
close the water
supply valve.
Please check
¿
rst
Is the POWER LED lit?
Does the LED light up when you
■
press [POWER ON/OFF] on the top
unit?
Is the breaker on the distribution
■
board turned on?
Check whether there is a power outage or
the breaker has turned "OFF".
POWER LED
POWER ON/OFF
Is the ENERGY SAVER LED lit?
While the LED is lit, energy-saver
■
(Page 24)
is in operation,
so the toilet seat temperature may be reduced or the
heater may be turned off.
Is the remote control working?
Is the Low Battery Warning LED
■
on the top surface of the remote
control
À
ashing?
Replace the batteries.
(Pages 14, 52)
Is the remote control transmitter
■
or the top unit receiver blocked?
Remove obstructions, dirt, water droplets
or any other blockages.
Battery cover
Open
e
Remote control transmitter
Top unit receiver
The remote control
uses batteries to
operate.
What to Do?
Freeze Damage Prevention
TCF9786JA only
In preparation for freezing conditions, such as in wintertime, take measures to prevent freezing.
Attention!
Do not use the energy-saver feature if there is a risk of the product being exposed to freezing temperatures.
●
(The product may be damaged)
Warm the bathroom so that the temperature around the product is not below freezing or take other appropriate
●
measures against freezing temperatures.
Before starting work, set "AUTO FLUSH"(Page 40) and "AUTO OPEN/CLOSE" (Page 42) to "OFF".
●
Dynamic mode
This method runs the water for the bowl unit and wand automatically at a fi xed interval in order to prevent freezing.
How to set
■
(Page 50)
Switch ANTI-FREEZING to ON with the remote control.
x
(Flashing: green)
The toilet flushes
at intervals of
about 10 minutes.
Water comes out from
near the wand at
intervals of 5 minutes.
Resupplying the Water
(After draining)
1
Open the water supply valve to supply water.
Check that there are no leaks in the plumbing or the Washlet.
x
2
[North, Central, South America]
If the power plug is disconnected, insert it.
[Asia, Oceania, Middle East]
If the breaker on the distribution board is set to OFF, switch it to ON.
3
Discharge water from the wand.
Press down the left side of the toilet seat.
1.
Press the "REAR CLEANSING" button on the remote control to discharge water from the wand.
2.
(Catch the water in a paper cup or other receptacle)
If the remaining water has frozen and no water comes out
■
Heat the inside of the bathroom, and warm the water supply hose and water supply valve using a
x
cloth soaked in warm water.
4
Press [FULL FLUSH] on the remote control to
À
ush.
If there is no water in the tank, you cannot fl ush the toilet. Never operate the toilet with no water in
x
the tank.
When the tank is fi lling with water, the LEDs on the main display will fl ash. When the tank becomes
full, the light remains to ON continuously.
(Tank fi lling time: approx. 30 seconds)
5
After the bowl unit
¿
lls with water, press [FULL FLUSH] again.
While ANTI-FREEZING is set to ON, it works as follows.
The POWER LED fl ashes.
x
The toilet fl ushes at intervals of about 10 minutes.
x
About 0.013 gal (about 50 ml) of water comes out from near the wand
x
at intervals of 5 minutes. (The wand remains retracted.)