TDP-S3/TDP-T3/TDP-MT5 Service Manual
52
Remove and replace the power supply fan and safety switch cable
The
power supply fan
(526-0098-xx) fastens to the metal chassis. It faces inward (label side in) so that it
blows cool air through the power supply. At the same time you remove the power supply fan cable, you
also remove the
safety switch cable
(211-0162-xx), which runs between the power supply and the
interlock switch assembly.
To remove and replace the safety switch cable, do the following:
1
Remove the chassis and power supply from the bottom case (see page 36).
2
Place the chassis on the work surface so that the power supply faces upward.
3
Unplug the safety switch cable from its connector on the power supply
4
Turn the chassis and power supply over on the work surface.
5
To remove the safety switch cable, lift it out of the three cable retainers on the chassis.
Summary of Contents for TDP-MT5
Page 1: ...DOCUMENT CREATED IN JAPAN Nov 2001 FILE NO 330 200106 ...
Page 76: ...TDP S3 TDP T3 TDP MT5 Service Manual 76 Fans No lamp page 36 page 89 page 89 page 29 page 36 ...
Page 79: ...TDP S3 TDP T3 TDP MT5 Service Manual 79 Fans lamp start then shut down page 89 page 29 ...
Page 82: ...TDP S3 TDP T3 TDP MT5 Service Manual 82 Bad color distortion torn or frozen image page 29 ...
Page 83: ...TDP S3 TDP T3 TDP MT5 Service Manual 83 Dim image page 17 page 29 page 57 ...
Page 84: ...TDP S3 TDP T3 TDP MT5 Service Manual 84 Troubleshooting Keypad Problems page 23 page 29 ...
Page 85: ...TDP S3 TDP T3 TDP MT5 Service Manual 85 Troubleshooting Remote Problems page 20 page 29 ...
Page 86: ...TDP S3 TDP T3 TDP MT5 Service Manual 86 Troubleshooting Menu Problems page 84 page 85 page 29 ...
Page 89: ...TDP S3 TDP T3 TDP MT5 Service Manual 89 Check controller voltages ...
Page 97: ...TDP S3 TDP T3 TDP MT5 Service Manual 97 ...
Page 108: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...