TDP-S3/TDP-T3/TDP-MT5 Service Manual
51
7
Do one of the following:
If you are replacing the power supply with a new one, follow the assembly notes below.
—Or—
Click the part below that you need to replace.
Rear bezel (see page 40)
Chassis (see page 43)
Assembly Notes
♦
Make sure the gap pad, the heat sink clip and the paper insulator are in place before you install the
power supply. Go to page 40 for more information.
♦
Align the power supply with the screw holes on the chassis. Once the power supply is in place, flex
the rear bezel outward so that the power supply ECA will clear the tab in the center of the rear bezel.
See step 6 above.
♦
Torque the six M3x8 Torx screws to 6 in-lbs (.68 Nm). See step 5 above for screw locations.
♦
Connect the ground wire to the post near the AC connector. Make sure that you route the wire as
shown below.
♦
Connect the interlock switch cable to its connector on the front of the power supply. See step 4
above.
Summary of Contents for TDP-MT5
Page 1: ...DOCUMENT CREATED IN JAPAN Nov 2001 FILE NO 330 200106 ...
Page 76: ...TDP S3 TDP T3 TDP MT5 Service Manual 76 Fans No lamp page 36 page 89 page 89 page 29 page 36 ...
Page 79: ...TDP S3 TDP T3 TDP MT5 Service Manual 79 Fans lamp start then shut down page 89 page 29 ...
Page 82: ...TDP S3 TDP T3 TDP MT5 Service Manual 82 Bad color distortion torn or frozen image page 29 ...
Page 83: ...TDP S3 TDP T3 TDP MT5 Service Manual 83 Dim image page 17 page 29 page 57 ...
Page 84: ...TDP S3 TDP T3 TDP MT5 Service Manual 84 Troubleshooting Keypad Problems page 23 page 29 ...
Page 85: ...TDP S3 TDP T3 TDP MT5 Service Manual 85 Troubleshooting Remote Problems page 20 page 29 ...
Page 86: ...TDP S3 TDP T3 TDP MT5 Service Manual 86 Troubleshooting Menu Problems page 84 page 85 page 29 ...
Page 89: ...TDP S3 TDP T3 TDP MT5 Service Manual 89 Check controller voltages ...
Page 97: ...TDP S3 TDP T3 TDP MT5 Service Manual 97 ...
Page 108: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...