5. SPECIFICATIONS OF ELECTRICAL PARTS
Outdoor Unit
No.
Parts name
Type
Specifications
1
Compressor
RA330A2T-20M
2
Outdoor fan motor
WDF-340-A100-1
Output 100W
3
High pressure switch
ACB-4UB83W
ON : 3.
2
MPa, OFF : 4.
15
MPa
4
PMV-Coil
CAM-MD12TCTH-7
DC12V
6
Reactor
CH-55-2Z-T
5
.
8
mH,
14
A
7
P.C.board for control and fan motor drive
MCC-1626
—
8
P.C.board for compressor drive
MCC-1627
—
9
Outdoor temp. sensor (TO sensor)
—
10 k
Ω
at 25°C
10
Discharge temp. sensor (TD sensor)
—
50 k
Ω
at 25°C
1
1
Suction temp. sensor (TS sensor)
—
10 k
Ω
at 25°C
1
2
Heat exchanger sensor (TE sensor)
—
10 k
Ω
at 25°C
1
4
Fuse (Mounted on P.C.board, MCC-1626)
50T 100H
T10A, 250V
1
5
Fuse (Mounted on P.C.board, MCC-1626)
50(P) 063HF GF001 C4
T6.3A, 250V
1
6
Fuse (Mounted on P.C.board, MCC-1626)
SCT 3.15A
3.15A, 250V
1
7
Fuse (Mounted on P.C.board, MCC-1627)
50(P) 063HF GF001 C4
T6.3A, 250V
1
8
Fuse (Mounted on P.C.board, MCC-1627)
GAC1 31.5A
31.5A, 500V
1
9
PTC Thermistor
MZ32-101RMARD01E
100
Ω
, 500V
5
Coil-value-4way
STF-H01AJ1872A1
AC220V ~ 240V
1
3
Heat exchanger sensor (T
L
sensor)
—
50
k
Ω
at 25°C
Output 3000W
- 22 -
FILE NO. SVM-17005