– 135 –
14 TE sensor
(Outdoor
heat
exchange
temperature)
∗
Attachment
Mount TE sensor on the straight part of the condenser
discharge port pipe so that the lead wire directs upward and
the sensor directs the liquid store tank.
NOTE
At working time (finish time), be sure not to
damage the cover of the sensor lead wire with
edge of sheet metal, etc.
If the cover of the sensor lead wire is
damaged, it is dangerous because an electric
shock or fire may be caused.
NOTE
After replacing of parts, check the sensors are
mounted at the specified positions.
If there are incorrect mounted positions,
control of the product does not operate
correctly and a trouble may be caused.
15 TS sensor
(Suction
temperature)
∗
Attachment
Insert TS sensor into the sensor holder welded to the
suction pipe and then mount it.
16 TD sensor
(Discharge
temperature)
∗
Attachment
Mount TD sensor on the straight part of the discharge pipe
so that the lead wire directs upward and the sensor directs
upward of the cabinet.
17 TO sensor
(Outside
temperature)
∗
Attachment
Insert TO sensor holder claw into the heat exchange
terminal block hole and then mount it.
No. Part name
Procedure
Remarks
Detail C
Detail F
Detail C
Detail D
Detail E
NOTE
NOTE
Detail D
Detail E
Detail F
Heat exchange
terminal block hole
TO sensor
holder