Test Program for Field.
Qosmio X500
Maintenance Manual (960-Q08)
7
NOTES
: The Item2 and 3 of Test Parameter are not used by some tests.
Go To Test
Move the highlight bar to
Go To Test
and press
Enter
to start executing the test.
Test Loop
Select
NO
to
return the screen to the subtest menu after the test is complete.
Select
YES
to
set the test to run continuously until it is halted by the user.
Error Stop
Select
NO
to keep the test running even if an error is found.
Select
YES
to stop the test program when an error is found and display the HALT
OPERATION screen as shown below:
[[ HALT OPERATION ]]
1: Test end
2: Continue
3: Retry
These three selections have the following functions:
1: Terminates the test program and exits to the subtest menu.
2: Continues the test from the error.
3: Restarts the test from the beginning.
Use the arrow keys to move the cursor to the desired option and press
Enter
.
Table 3-1 in Section 3.3 lists the function of each test on the subtest menu. Table 3-2 in
Section 3.15 lists the error codes and error status for each error.