Replacement Procedures
Qosmio X500 Maintenance Manual (960-Q08)
61
Installing the LCD unit/FL Inverter
The following describes the procedure for installing the LCD unit and FL inverter.
Install the LCD supports (LCD unit side) and hinge to the LCD and secure them with the
following
screws
.
M2.0
2.5 BINK screw
x8
1.
Stand the
LCD unit
on the display cover and connect the
LCD harness
to the
connector on the back of LCD.
2.
Stick the
conductive tape
on the connector of LCD harness.
3.
Secure the LCD unit with the following
screws
.
M2.5x4.0
screw
x2
M2.5x5.0
screw
x8
4.
Connect
LCD harnesses
to the connector
CN1
of the inverter.
CAUTION:
Be careful not to connect the LCD harnesses to the wrong connectors of FL
inverter.
5.
Connect
HV harnesses
to the connector
CN2
of the FL inverter.
6.
Install the
display mask
while fitting the latches.
7.
Secure the display mask with following
screws
M2.5
6.5
screw X8
8.
Cover screws with Screw MYLAR cover X8
NOTE:
When installing the display mask, make sure there is no gap between the display
mask and the display cover.