Replacement Procedures
Opening the display to 135degree, and remove the hinge screw.
‧
M2.5
6.5 FLAT BIND screw
x6 (Locktight)
Figure 4-13-5 Remove the hinge screws
11.
Pulling out the
pole of hinge
from the
hole
of hinge assembly, remove the
display
assembly
from the base assembly.
Installing display assembly
The following describes the procedure for installing the display assembly.
1.
Inserting the
pole
of hinge
to the
hole
of hinge assembly, set the
display assembly
on the base assembly.
2.
Secure the
hinges
with the following
screws
secure the
display mask
with the
following
screws
and stick the
mask seal
on them.
M2.5
6.5 FLAT BIND screw
x6 (Locktight)
NOTE
: Be sure to apply the locktight to the screws instructed in the figure above.
3.
Connect the
LCD harness
to the connector on the system board.