Test Program for Field.
3.18 Log Utilities
This function logs error information generated while a test is in progress and stores the
results in RAM (Maximum error log : 500 times). This function can store data on a floppy
disk. If the power switch is turned off, the error information will be lost. Error information is
displayed in the following order:
1.
Error count (CNT)
2.
Test name and subtest number (TEST)
3.
Pass count (PASS)
4.
Error status (STS)
5.
FDD/HDD or memory address (ADDR)
6.
Write data (WD)
7.
Read data (RD)
8.
Error Name ( ERROR NAME/DETAILS)
3.18.1 Operations
1.
Select
04
and press
Enter
in the Diagnostics Menu to log error information into
RAM or onto a floppy disk. Error information is displayed in the following format:
XXXX ERRORS
PASSCOUNT = XXXX
CNT TEST
PASS STS ADDR
WD RD ERROR
NAME/DETAILS
001 FDD
02 0000 180 0000001 00 00 WRITE
PROTECTED
002 FDD
01 0000 120 0000001 00 00 TIME
OUT
ERROR
Address
Error
Status
Pass
Count
Subtest Number
Read Data
Test
Name
Write
Data
Error Count
Error Name and Detail
[[1:Next, 2:Prev, 3:Exit, 4;Clear, 5:FD Log Read, 6:FD Log Write, 7:Log Save]]
Qosmio X500
Maintenance Manual (960-Q08)
63
Summary of Contents for Qosmio X500
Page 13: ...Qosmio X500 Maintenance Manual 960 Q08 ...
Page 14: ...Qosmio X500 Maintenance Manual 960 Q08 Chapter 1 Hardware Overview ...
Page 42: ...2 1 Qosmio X500 Maintenance Manual 960 Q08 Chapter 2 Troubleshooting Procedures ...
Page 86: ...Test Program for Field Qosmio X500 Maintenance Manual 960 Q08 1 Chapter 3 Diagnostic Programs ...
Page 277: ...Wiring Diagrams Qosmio X500 Maintenance Manual 960 Q08 F 2 ...