Connecting Hardware Devices
Expansion Cards
81
Installing a RAID Controller
1
If the server is in operation, shut it down then remove the access cover. For detailed
instructions, read the
Maintenance Overview
on page 50.
2
Disconnect the SCSI cable from the motherboard.
3
Lift the card support on the bottom PCI slot and remove the expansion slot cover.
4
Connect the SCSI cable to the SCSI connector on the RAID controller and connect
the SCSI cable to channel 1 when installing a RAID card that has two internal hard
disk drive connectors. For more information, refer to the user’s guide that came with
the RAID controller.
5
Reinstall the access cover, reconnect all signal and power cables, then turn on the
server. For instructions, read the
Maintenance Overview
on page 50.
6
Install the configuration software for the RAID card, then set up the disk array
(RAID). For instructions, refer to the user’s guide that came with the RAID controller.
CAUTION: Installing the RAID controller while the power is on may damage the
server and the RAID controller.
CAUTION: To avoid damaging the SCSI cable, grasp the cable connector when
disconnecting the cable.