2. Copier-specific Adjustments
is mainly adjusted. Setting “2” for the subcode allows you to adjust the high-density area. But it will not
affect the background density. Therefore, never change the value for the high-density area.
Subcode
Area where the density is adjusted
0
Low-density area
1
Medium-density area
After adjusting the gamma curve balance, copy and check the copy image quality.
If further image quality adjustments are still necessary, use the next procedure.
Caution after the adjustment
The adjustment may possibly cause text handwritten with a pencil or light text to become illegible on the copy.
Therefore, carefully perform the adjustment, while checking the copy image.
Remarks
Enter a value within the recommended value range mentioned in the procedures. Otherwise, it may cause a loss in
MFP performance, including degradation in the image quality.