1. General Adjustments – Copying, Printing and e-Filing (Output from Box)
(b)
Set "5" or "3" for code 08-2508 to increase the frequency of image quality control, in response to a
change in humidity.
* Image quality control will be performed, when the drum temperature changes in accordance with the
difference from the previous image quality control. If the difference in the drum temperature exceeds
the specified value after a print job is performed, image quality control is performed.
Value for 08-2508
Difference in drum temperature
3
3°C
5
5°C
7
7°C (default)
•
After setting the value for code 08-2505, forcibly perform image quality control, as follows:
Select [05 ADJUSTMENT MODE]. Select code [2742]. Press the [START] button.
(1)-3. To Have Uniform Variations in the Image Quality after Return from the Auto Power Save
Mode:
Change the value of the [08] code [2507] to change the conditions for starting image quality control (shorten
the period of time the MFP is left unused) after the MFP was recovered from the auto power save mode, so
that the image quality control will be easily performed.
Image quality control is performed before the start of a job.
For a more stable image quality on halftones, switch the image quality control to start to the Full Mode with
code 08-2492. (0: Disabled, 1: Short, 2: Full)
Value for
08-2507
Period of time the MFP is left unused before starting image quality control
0
3 minutes or longer
1
5 minutes or longer
2
7 minutes or longer
3
10 minutes or longer
4
15 minutes or longer
5
20 minutes or longer
6
30 minutes or longer
7
45 minutes or longer
8
60 minutes or longer
9
90 minutes or longer
10
120 minutes or longer
11
150 minutes or longer
12
180 minutes or longer
13
240 minutes or longer
14
300 minutes or longer
15
360 minutes or longer (default value)