2-12
2. Copier-specific Adjustments
(1) Perform automatic calibration to correct variations in the copy density.
* [ADMIN] is selected from among the [CALIBRATION DISPLAY LEVEL] options by default. In other
words, an administrator is authorized to operate automatic calibration. But the [USER] option can also be
selected to allow the user to operate it. Refer to the MFP Management Guide for further information
regarding how to select the [CALIBRATION DISPLAY LEVEL] option.
•
Use steps (a) through (i) to perform automatic calibration.
(a) Press [USER FUNCTIONS] on the Control Panel to enter the “User Functions” menu.
(b) Press [ADMIN].
(c) Enter an administrator password of 6 to 64 digits. Press [ENTER].
(d) Press [GENERAL].
(e) Press [CALIBRATION].
(f) Press [COPY].
(g) Press [CALIBRATION] to print out the test chart.
(h) Place the printed test chart on the original glass.
(i) Press the [START] button to perform calibration. When the calibration comes to an end, the message
“Scanning and calibrating” will disappear.
* As a result of the above steps, the copy image quality will be corrected in the Full color mode and
the Black and White mode simultaneously.
After performing automatic calibration, copy and check the copy image quality.
If further image quality adjustments are still necessary, use the next procedure.