November 2003 © TOSHIBA TEC
2 - 53
e-STUDIO3511/4511 ERROR CODE AND SELF-DIAGNOSTIC MODE
Text
/Photo
Photo
Text
Text
/Photo
Photo
Text
L
M
H
L
M
H
L
M
H
L
M
H
Range correction
Background peak
adjustment
Range correction
on original
manually set on
the original glass
Automatic gamma adjust-
ment
Adjustment of
gamma balance
(Text/Photo)
Adjustment of
gamma balance
(Text)
Adjustment of
gamma balance
(Photo)
Adjustment of
gamma balance
(PS/Smooth)
Adjustment mode (05)
Code
Classifi-
cation
Items
Func-
tion
Default
<Acceptable
value>
RAM
Contents
Proce-
dure
532
533
534
570
571
572
580
590-0
590-1
590-2
591-0
591-1
591-2
592-0
592-1
592-2
596-0
596-1
596-2
Image
Image
Image
Image
Image
Image
Image
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PPC
(black)
PRT
(black)
PRT
(black)
PRT
(black)
40
<0-255>
16
<0-255>
40
<0-255>
22
<11-14,
21-24,
31-34,
41-44>
12
<11-14,
21-24,
31-34,
41-44>
22
<11-14,
21-24,
31-34,
41-44>
-
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
128
<0-255>
SYS
SYS
SYS
SYS
SYS
SYS
-
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
When the value increases, the
background of the image (low density
area) becomes harder to be printed
out.
Sets whether the values of the
background peak and text peak are
fixed or not. One’s place is an
adjustment for “automatic density”
and ten’s place is for “manual
density”. Once they are fixed, the
range correction is performed with
standard values. The values of the
background peak and text peak affect
the reproduction of the background
density and text density respectively.
Background peak
Text peak
1:
fixed
fixed
2:
varied
fixed
3:
fixed
varied
4:
varied
varied
Adjusts the gradation reproduction
automatically.
When the value increases, the
density in the target area becomes
higher.
L : Low density area
M : Medium density area
H : High density area
1
1
1
1
1
1
7
4
4
4
4
4
4
4
4
4
4
4
4
Summary of Contents for e-STUDIO3511
Page 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Page 10: ...e STUDIO3511 4511 CONTENTS vi November 2003 TOSHIBA TEC ...
Page 12: ......
Page 20: ...e STUDIO3511 4511 SPECIFICATIONS 1 8 November 2003 TOSHIBA TEC ...
Page 190: ...e STUDIO3511 4511 ERROR CODE AND SELF DIAGNOSTIC MODE 2 170 November 2003 TOSHIBA TEC ...
Page 456: ...e STUDIO3511 4511 TROUBLESHOOTING 5 142 November 2003 TOSHIBA TEC ...
Page 518: ...e STUDIO3511 4511 FIRMWARE UPDATING 6 62 November 2003 TOSHIBA TEC ...
Page 546: ...e STUDIO3511 4511 REMOTE SERVICE 8 24 November 2003 TOSHIBA TEC 7 ...
Page 548: ...e STUDIO3511 4511 WIRE HARNESS CONNECTION DIAGRAMS 9 2 November 2003 TOSHIBA TEC ...
Page 551: ......
Page 552: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...