November 2003 © TOSHIBA TEC
4 - 19
e-STUDIO3511/4511 PREVENTIVE MAINTENANCE
Head of color auto-toner sensor
Color auto-toner
sensor unit
Reference plate
Color auto-toner
sensor unit
*j3.
Color auto-toner sensor
The head of color auto-toner sensor is to be cleaned with a cotton swab or soft cloth with
sufficient alcohol filled in. The reference plate is to be cleaned by blowing off the adhered toner
with an air-spray type cleaner such as a blower brush or an air duster.
During replacement, coat the shaft of sensor shutter with the grease (Alvania No.2).
Fig. 4-212
Note:
Never clean the reference plate by touching it directly (e.g. brushing away the dust) since the
surface of reference plate will be scratched.
*j4.
Polarity adjustment plate
Apply two-rice-grain-amount of FLOIL (GE-334C) to the polarity adjustment plate (feeding ter-
minal).
05/03
Fig. 4-213
*j5.
Color toner cartridge sensor
Perform the cleaning of the surface of the color toner cartridge sensor when you replace the
color developer unit (e-STUDIO3511: 30,000 sheets / e-STUDIO4511: 37,500 sheets).
*j6.
Front bearings of mixers
When exchanging the oil seals (rear side of mixer-1 and -2) of the color developer unit, replace
the front bearings of mixer-1 and -2 at the same time. Since the oil seal is attached to the front
bearings of mixer-1 and -2, apply grease when replacing them referring to *j2.
Summary of Contents for e-STUDIO3511
Page 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Page 10: ...e STUDIO3511 4511 CONTENTS vi November 2003 TOSHIBA TEC ...
Page 12: ......
Page 20: ...e STUDIO3511 4511 SPECIFICATIONS 1 8 November 2003 TOSHIBA TEC ...
Page 190: ...e STUDIO3511 4511 ERROR CODE AND SELF DIAGNOSTIC MODE 2 170 November 2003 TOSHIBA TEC ...
Page 456: ...e STUDIO3511 4511 TROUBLESHOOTING 5 142 November 2003 TOSHIBA TEC ...
Page 518: ...e STUDIO3511 4511 FIRMWARE UPDATING 6 62 November 2003 TOSHIBA TEC ...
Page 546: ...e STUDIO3511 4511 REMOTE SERVICE 8 24 November 2003 TOSHIBA TEC 7 ...
Page 548: ...e STUDIO3511 4511 WIRE HARNESS CONNECTION DIAGRAMS 9 2 November 2003 TOSHIBA TEC ...
Page 551: ......
Page 552: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...