e-STUDIO3511/4511 ADJUSTMENT
3 - 62
November 2003 © TOSHIBA TEC
Step 3
Case E: Adjust the reverse aligning adjustment position to the rear side “-” of the original (
Chapter
3.12.6).
Case F: Adjust the reverse aligning adjustment position to the rear side “+” of the original (
Chapter
3.12.6).
Paper
Original
3.12.4 Automatic adjustment of sensors and initialization of EEPROM
When any of the PC board, original length sensor, read sensor, reverse sensor is replaced with a new
one, make sure to perform the initialization of EEPROM and adjustment of sensors in the Adjustment
Mode (05).
Perform them after removing all originals on the sensor and closing the RADF.
Also, make sure to adjust the tray volume when the initialization of EEPROM and automatic sensor
adjustment have been performed.
Refer to “2.2.4 Adjustment Mode (05)” for the details.
Errors such as paper jamming may occur if the EEPROM is not initialized and the sensors are not
adjusted after the above mentioned parts were replaced.
Fig. 3-1219
Summary of Contents for e-STUDIO3511
Page 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Page 10: ...e STUDIO3511 4511 CONTENTS vi November 2003 TOSHIBA TEC ...
Page 12: ......
Page 20: ...e STUDIO3511 4511 SPECIFICATIONS 1 8 November 2003 TOSHIBA TEC ...
Page 190: ...e STUDIO3511 4511 ERROR CODE AND SELF DIAGNOSTIC MODE 2 170 November 2003 TOSHIBA TEC ...
Page 456: ...e STUDIO3511 4511 TROUBLESHOOTING 5 142 November 2003 TOSHIBA TEC ...
Page 518: ...e STUDIO3511 4511 FIRMWARE UPDATING 6 62 November 2003 TOSHIBA TEC ...
Page 546: ...e STUDIO3511 4511 REMOTE SERVICE 8 24 November 2003 TOSHIBA TEC 7 ...
Page 548: ...e STUDIO3511 4511 WIRE HARNESS CONNECTION DIAGRAMS 9 2 November 2003 TOSHIBA TEC ...
Page 551: ......
Page 552: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...