November 2003 © TOSHIBA TEC
3 - 71
e-STUDIO3511/4511 ADJUSTMENT
A
B
(7)
Adjust the position of the front jogging plate
home position sensor (S6) with reference to
the index.
EX. 1
If the width is 319 mm in step (2), the
difference from the standard is +2 mm, it
requires relocation of the sensor [3] in the
direction of arrow A by 2 mm.
EX. 2
If the width is 316 mm in step (2), the
difference from the standard is -1 mm; it
requires relocation of the sensor [3] in the
direction of arrow B by 1 mm.
Fig. 3-1304
Screw
Home position
sensor plate
Sensor
Fig. 3-1305
(4)
Measure the jogging width (standard at 317
mm).
(5)
Remove the processing tray.
(6)
Loosen the screw on the home position
sensor plate at the front.