e-STUDIO3511/4511 TROUBLESHOOTING
[Procedure 2]
Does the bushing attached to the returning roller shaft smoothly move up and down?
NO
Apply grease on the cut-out part of the front side frame with where the bushing contacts.
YES
Is the spring of the returning roller detached?
YES
Attach the spring.
NO
Is the tension of the stack processing motor drive belt normal?
NO
Loosen the adjustment screw to adjust its tension.
YES
Is the returning roller home position sensor (S3) working properly?
NO
Replace the sensor.
YES
1. Replace the stack processing motor.
2. Replace the finisher controller PC board.
[CC40] Swing motor abnormality
MJ-1023/1024
Is the swing unit home position sensor (PI35) normal?
NO
Replace the sensor.
YES
Is the wiring between the finisher controller PC board and the swing motor (M36) correct?
NO
Correct the wiring.
YES
Is the swing mechanism normal?
NO
Fix the mechanism.
YES
1. Replace the swing motor.
2. Replace the finisher controller PC board.
Summary of Contents for e-STUDIO3511
Page 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Page 10: ...e STUDIO3511 4511 CONTENTS vi November 2003 TOSHIBA TEC ...
Page 12: ......
Page 20: ...e STUDIO3511 4511 SPECIFICATIONS 1 8 November 2003 TOSHIBA TEC ...
Page 190: ...e STUDIO3511 4511 ERROR CODE AND SELF DIAGNOSTIC MODE 2 170 November 2003 TOSHIBA TEC ...
Page 456: ...e STUDIO3511 4511 TROUBLESHOOTING 5 142 November 2003 TOSHIBA TEC ...
Page 518: ...e STUDIO3511 4511 FIRMWARE UPDATING 6 62 November 2003 TOSHIBA TEC ...
Page 546: ...e STUDIO3511 4511 REMOTE SERVICE 8 24 November 2003 TOSHIBA TEC 7 ...
Page 548: ...e STUDIO3511 4511 WIRE HARNESS CONNECTION DIAGRAMS 9 2 November 2003 TOSHIBA TEC ...
Page 551: ......
Page 552: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...