e-STUDIO3511/4511 TROUBLESHOOTING
5 - 114
November 2003 © TOSHIBA TEC
(7)
Blurred image
Feeding direction
Cause/Section
Scanner
Drum
Ozone exhaust
Step
1
2
3
4
Check items
Is the scanner bedewed?
Is the drum bedewed or dirty?
Is the ozone exhaust fan operating
properly?
Is the ozone filter stained or damaged?
Measures
Clean it.
Wipe the drum with dry cloth.
* Be sure never use alcohol or other
organic solvents because they have
bad effect on the drum.
Check the connection of the connector.
Replace it.
Fig. 5-208