
e-STUDIO3511/4511 ADJUSTMENT
3 - 66
November 2003 © TOSHIBA TEC
(4)
Fix the plate spring temporarily with the
screw on the left. Then press the plate
spring slightly in the direction of an arrow
and tighten the screw in the position where
the gap (D) between the plunger and the
flapper lever is eliminated.
D
D
Plunger
Flapper lever
Fig. 3-1225
Summary of Contents for e-STUDIO3511
Page 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Page 10: ...e STUDIO3511 4511 CONTENTS vi November 2003 TOSHIBA TEC ...
Page 12: ......
Page 20: ...e STUDIO3511 4511 SPECIFICATIONS 1 8 November 2003 TOSHIBA TEC ...
Page 190: ...e STUDIO3511 4511 ERROR CODE AND SELF DIAGNOSTIC MODE 2 170 November 2003 TOSHIBA TEC ...
Page 456: ...e STUDIO3511 4511 TROUBLESHOOTING 5 142 November 2003 TOSHIBA TEC ...
Page 518: ...e STUDIO3511 4511 FIRMWARE UPDATING 6 62 November 2003 TOSHIBA TEC ...
Page 546: ...e STUDIO3511 4511 REMOTE SERVICE 8 24 November 2003 TOSHIBA TEC 7 ...
Page 548: ...e STUDIO3511 4511 WIRE HARNESS CONNECTION DIAGRAMS 9 2 November 2003 TOSHIBA TEC ...
Page 551: ......
Page 552: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...