e-STUDIO3511/4511 ADJUSTMENT
3 - 56
November 2003 © TOSHIBA TEC
3.12 Adjustment of the RADF (MR-3015)
3.12.1 Adjustment of RADF position
It is mainly performed at the installation. It is also required when the RADF is dislocated for some reason
such as moving the equipment.
Remove the platen sheet during adjustment.
(1)
Open the RADF and then attach 2
positioning pins to the equipment.
(The positioning pins have been attached at
the rear of the right-hand hinge of the
RADF.)
(2)
Close the RADF to check that the
positioning pins fit smoothly into the holes
on the RADF.
If they do not, adjust them according to the
following procedure.
(3)
Loosen the stepped screw 1 turn and 2
screws on the adjustment plate a half turn
(status of temporary fixing).
Half turn
1 turn
Positioning
pin
Fig. 3-1201
Fig. 3-1202
Fig. 3-1203
Summary of Contents for e-STUDIO3511
Page 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Page 10: ...e STUDIO3511 4511 CONTENTS vi November 2003 TOSHIBA TEC ...
Page 12: ......
Page 20: ...e STUDIO3511 4511 SPECIFICATIONS 1 8 November 2003 TOSHIBA TEC ...
Page 190: ...e STUDIO3511 4511 ERROR CODE AND SELF DIAGNOSTIC MODE 2 170 November 2003 TOSHIBA TEC ...
Page 456: ...e STUDIO3511 4511 TROUBLESHOOTING 5 142 November 2003 TOSHIBA TEC ...
Page 518: ...e STUDIO3511 4511 FIRMWARE UPDATING 6 62 November 2003 TOSHIBA TEC ...
Page 546: ...e STUDIO3511 4511 REMOTE SERVICE 8 24 November 2003 TOSHIBA TEC 7 ...
Page 548: ...e STUDIO3511 4511 WIRE HARNESS CONNECTION DIAGRAMS 9 2 November 2003 TOSHIBA TEC ...
Page 551: ......
Page 552: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...