e-STUDIO181/211
© 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 54
1410
Counter
Counter for period of toner
cartridge rotation time
ALL
0
<8 digits>
M
Counts up the period of
rotation time of the
toner cartridge.
1
1411
Counter
Counter for envelope
ALL
0
<8 digits>
M
Counts up when the
registration sensor is
ON.
1
1628-0
Processi
ng
Drum life correction
switching of the drum
reverse rotation amount
ALL
4
<0-15>
M
Drum life correction
switching of the drum
reverse rotation amount
1
1628-1
Processi
ng
Drum life correction
switching of the normal
drum rotation amount after
the reverse rotation
ALL
9
<0-15>
M
Drum life correction
switching of the normal
drum rotation amount
after the reverse
rotation
1
1913
Processi
ng
The function clear LED
blinks
PPC
1
<0-1>
SYS
Blinks when the value is
different from the
present default value
after copying (until auto
clear or all clear.)
0: Invalid (Always off)
1: Valid
1
Setting mode (08)
Code
Classific
ation
Items
Funct
ion
Default
<Accept
able
value>
RAM
Contents
Proce
dure
Summary of Contents for e-STUDIO181
Page 14: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 138: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 56 ...
Page 202: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Page 220: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Page 222: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Page 225: ......
Page 226: ......