e-STUDIO181/211
© 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 14
[D] Image position adjustment of the secondary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) Press [0] and [9] simultaneously to enter the normal mode.
(4) Make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment.
(5) Press [0] and [5] simultaneously to enter the adjustment mode.
(6) Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(7) Check if the distance D is within the range of 10±0.5 mm.
(8) If not, use the following procedure to change values and repeat the steps (3) to (7) above.
(Adjustment Mode) (Key in the code [305]) [START]
(Key in a value (acceptable values: 51 to 206))
Press the [INTERRUPT] button (stored in memory: The density LED blinks.). (“AJ” is
displayed.)
*The larger the adjustment value is, the more the image is shifted to the trailing edge (0.064 mm/
step).
Be sure not to perform any operations while the density LED is blinking.
Fig. 3-11
10
20
30
40
D
Feeding direction
Copied image of the ruler
Summary of Contents for e-STUDIO181
Page 14: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 138: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 56 ...
Page 202: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Page 220: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Page 222: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Page 225: ......
Page 226: ......