3
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO181/211
ADJUSTMENT
3 - 27
3.5.2
Sharpness adjustment
If you want to make scan images look softer or sharper, perform the following adjustment.
< Adjustment Mode (05) >
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in the sub code (0,1 or 2), and press the [START] button.
(4) Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
(5) Press the [INTERRUPT] button to store the value in memory. The equipment goes back to the
ready state.
(6) For resetting the value, repeat step (2) to (5).
(7) Turn the power OFF and then back ON to perform scanning job.
(8) If the desired image density has not been attained, repeat step (2) to (7).
Original mode
Item to be adjusted
Remarks
Text/Photo
Photo
Text
865-0
867-0
866-0
Reproduction ratio:
25% to 40%
Key in the following values
depending on the original mode.
One’s place
Selecting a filter shape
Ten’s place
0: Use Default value
1 to 9: Change intensity
•
The larger the value is, the
sharper the image becomes.)
•
Example of value entry in case
the mode is “Text/Photo”.
Note:
When the value “0” is keyed in
at the ten’s digit, the value is
not displayed on LCD screen.
865-1
867-1
866-1
Reproduction ratio:
41% to 80%
865-2
867-2
866-2
Reproduction ratio:
81% to 400%
2 1
Fixed value for Text/
Photo mode
Key in a value 0 to 9
Summary of Contents for e-STUDIO181
Page 14: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 138: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 56 ...
Page 202: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Page 220: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Page 222: ...e STUDIO181 211 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Page 225: ......
Page 226: ......