Replacing Consumables / Maintenance Units
- 64 -
2
1
3
4
5
6
7
2
Hold the Document holder lever and lift the
Document holder.
3
Insert your finger into the recess on the
right side of the machine and pull the front
cover open lever to open the front cover
forward.
Note
• Open the front cover gently. If you open it rapidly, the
bypass tray may open.
4
Open the top cover.
Note
• If the inner finisher is installed, be sure to remove any
output paper on it before opening the top cover.
5
Remove the print cartridge and place it on a
flat surface.
Note
• The image drum (the green tube) of the print cartridge
is very delicate. Handle it carefully.
• Do not expose the print cartridge to direct sunlight or
very bright interior light (approximately more than
1,500 lux). Even under the normal interior light, do not
leave it for more than 5 minutes.
6
Cover the removed print cartridge with
paper so that it will not be exposed to light.
7
Hold the handle of the fuser unit and lift the
fuser unit out of the machine.
Document
holder
Document
holder lever
Front Cover
Front Cover
Open Lever
Possible to get burned.
Since the fuser unit gets hot, carry out the
operation carefully, and when lifting it up you must
hold it by the handle. Do not try to hold it whilst it is
hot. Wait until it has cooled down and then carry
out the operation.
Caution
Top cover
Print Cartridge