e-STUDIO202S SIMULATION, TROUBLE CODES 10 - 8
26
62
Energy-save mode copy lamp setup
Used to set half-ON (50%)/OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the
START key to enable the setup.
30
01
Paper sensor status display
Indicates the paper sensor status using the lamps on the operation panel.
41
06
OC cover float detection level adjustment <ADF model only>
When this simulation is executed, the current set value is displayed.
When START key is pressed, the mirror base unit moves to the ADF scanning position and the OC cover float detection level
(number of pixels between black lines) is acquired and displayed.
The value (0000) is displayed on the 7seg in 2 digits for each.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the value is not acquired, an error is displayed as shown below. (Default: 0)
The status display is as shown below.
The JAM lamp is lighted. (The 7seg display remains to the original value.)
Note that the OC cover must be closed when executing this simulation.
∗
When the value is 0, float detection is not performed in a normal job.
When C key is pressed, the display returns to the sub code input standby state.
07
OC cover float detection margin setting <ADF model only>
For the number of pixels between black markers on the ADF scanning position saved in SIM 41-06 (OC cover float detection
level adjustment), if the number of pixels between the markers when processing float detection is less than the number of
pixels set with this simulation, it is judged as the float error.
In addition, if the set value of this simulation is 0, no float error occurs.
When this simulation is executed, the current set value is displayed.
Enter the adjustment value with UP/UP key, and press START key to save the entered value. The display returns to the sub
code input standby mode.
Set range: 0 – 99
Default: 30 (30 pixels)
43
01
Fusing temperature setting (Normal copy)
Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2nd sheets, SIM 43-14 is used.)
When this simulation is executed, the currently set code number is displayed.
Enter the code number with UP/UP key and press START key. The entered value is saved and the display returns to the sub
code input standby state.
The exposure select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
∗
The cassette feed and the manual feed are controlled similarly.
Main
code
Sub
code
Content
Code number
Setup
0
Copy lamp OFF
1
Copy lamp half-ON (50%) * Default
Sensor name
Display lamp
Before-resist paper sensor (PPD1)
Developer cartridge replacement lamp
Fusing section paper sensor (PPD2)
JAM lamp
Paper exit sensor (POD)
Photoconductor cartridge replacement lamp
2nd CS paper sensor (PPD3)
2nd cassette lamp
New drum cartridge sensor (PUIS)
Zoom lamp
Code number
Set temperature (°C)
0
170
1
175
2
180
3
185
4
190
5
195 (* Default)
6
200
7
205
8
210
Mode
Lamp ON
Main cassette paper feed & 2nd cassette paper feed
AE mode lamp
Manual paper feed
TEXT mode lamp