75
Deutsch
English
Display
Cause
What to do
E21
remote throttle calibration
defective
• Re-calibrate:
Press “cal” button for 10 seconds.
• The display shows “cal up”:
Press remote throttle lever forward to full gas then press
the “cal” button.
• The display shows “cal stp”:
Return remote throttle lever to central (stop) position then
press the “cal” button.
• The display shows “cal dn”:
Press remote throttle lever reverse to full gas then press
the “cal” button.
E22
Magnetic sensor defective Re-calibrate (refer to E21).
E23
Value range false
Re-calibrate (refer to E21).
E30
Motor communication
error
Check the motor cable’s plug-in connection.
Check the motor cable for damage.
E32
Remote throttle
communication error
Check the remote throttle‘s connections.
Check the cable.
E33
Internal error
• Overcurrent of 5V bus/-USB supply –
> Check cable of tiller/remote throttle, remove additional
devices such as TorqTrac and USB connection, and switch
system on/off.
• Error is displayed immediately after turning on the battery
and can be reset by the tiller / the remote throttle. -> Pa-
rameter error, error in the EEPROM. Contact the Torqeedo
Service Center.
E36
Overvoltage battery/
engine
For external drive (towing the boat, sailing, operating with
another engine), the propeller is to be taken out of the
water. If the error occurs during/after charging the battery
contact the Torqeedo Service Center.
E41
Excessive charging
voltage / charging current
too high
If the error occurs despite the use of a Torqeedo power
supply, contact the Torqeedo Service Center.
E42
Power fuse defective
Battery only starts when charging cable is plugged in.
Contact Torqeedo Service Center.
E43
Battery empty
Charge battery. Motor can be used again slowly from the
stop position.
E45
Battery overcurrent
Switch motor off and on again. If this error occurs the batte-
ry status indicator and range display can no longer operate
until the battery has been fully charged again.
E46
Battery operating tempe-
rature fault
Battery cells outside operating temperature between -20°C
and +60°C (-4°F and +140°F).
The motor can be used again when the temperature has
stabilized.
E48
Charging temperature
error
Allow battery to cool; charging will continue when the cell
temperature is between 0°C and +45°C (32°F and 113°F).
E49
Battery is exhaustively
discharged
Contact Torqeedo Service Center.
Other error
codes
Faulty
Contact Torqeedo Service and notify them of the error code.
Nothing
displayed/ no
flashing during
charging
Battery does not charge
Contact Torqeedo Service Center.