Important:
Ensure that the hoses are
routed away from any moving, sharp, or hot
components.
5.
Visually inspect the hydraulic system for leaks,
loose fasteners, missing parts, and improperly
routed lines. Make all repairs before operating.
Product Overview
Controls
Gate Metering Control
The black knobs on the left rear side of the machine
are used to adjust and lock the gate into the desired
open height position.
1.
Loosen the locking knob (
) enough to
allow it to slide freely in the slot.
2.
Set the gate knob (
) into the desired
position and tighten the locking knob to secure
the adjustment.
Rate Scale
Use the rate scale (
) to determine the desired
flow rate. Refer to
Sand Application Rate (page 18)
.
g266287
Figure 19
1.
Gate adjusting knob
3.
Rate scale
2.
Gate locking knob
13