Main Contactor
g339029
Figure 61
1.
Contactor
3.
TEC
2.
Bolt (2 each)
The Greensmaster e1021/e1026 machines use the main contactor to connect
the lithium battery pack and the electric motor. The contactor is energized by
the TEC.
The contactor is attached to the battery mount under the battery cover; refer
to
Note:
When the key switch is turned to the START position, the contactor
inside the battery pack will be energized followed shortly by the main contactor
being energized. There should be an audible click as each of these contactors
are energized.
Note:
A damaged main contactor may cause a #16 fault to be generated
and displayed on the InfoCenter. Refer to the
Faults Screen (page 5–15)
for
information on faults.
Testing the Main Contactor
1. Park the machine on a level surface and make sure that the clutch bail in the
NEUTRAL position. Turn the key switch to the OFF position and remove
the key from the key switch.
2. Disconnect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 5–3)
.
3. Remove the four bolts that secures the battery cover to the battery mount.
Remove the battery cover from the machine.
Electrical System: Testing the Electrical Components
Page 5–36
Greensmaster
®
e1021/e1026
20246SL Rev A
Summary of Contents for 04831
Page 4: ...NOTES NOTES Page 4 Greensmaster e1021 e1026 20246SL Rev A ...
Page 6: ...g340650 Figure 1 Model 04831 shown Preface Page 6 Greensmaster e1021 e1026 20246SL Rev A ...
Page 14: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster e1021 e1026 20246SL Rev A ...
Page 136: ...Electrical System Service and Repairs Page 5 56 Greensmaster e1021 e1026 20246SL Rev A ...
Page 216: ......