103
FUNCTION SETTING USING SETTINGS
Optotype of
Landolt's ring
simulation 1
(Upper)
Set by ten-key display. Optotype of Landolt's ring simulation 1 (upper) is set.
10 to 200 (changeable with 10 steps)
100
Optotype of
Landolt's ring
simulation 2
(Middle)
Set by ten-key display.
Optotype of Landolt's ring simulation 1 (middle) is
set. 10 to 200 (changeable with 10 steps)
40
Optotype of
Landolt's ring
simulation 3
(Lower)
Set by ten-key display.
Optotype of Landolt's ring simulation 1 (lower) is set.
10 to 200 (changeable with 10 steps)
20
Landolt Direction
Upper
Direction of Landolt's ring is set to Upper.
Right
Lower
Direction of Landolt's ring is set to Lower.
Right
Direction of Landolt's ring is set to Right.
Left
Direction of Landolt's ring is set to Left.
Normalize
destiny of
simulations
ON
Normalization of brightness in Landolt's ring
simulation is set.
OFF
OFF
Normalization of brightness in Landolt's ring
simulation is not set.
Sph Step
0.25D
Display step of spherical/corneal refractive power is
set to 0.25D
0.25D
0.12D
Display step of spherical/corneal refractive power is
set to 0.12D.
0.01D
Display step of spherical/corneal refractive power is
set to 0.01D.
Cyl Step
0.25D
Display step of cylindrical refractive power/corneal
astigmatic power is set to 0.25D.
0.25D
0.12D
Display step of cylindrical refractive power/corneal
astigmatic power is set to 0.12D.
0.01D
Display step of cylindrical refractive power/corneal
astigmatic power is set to 0.01D.
Axis Step
1°
Display step of astigmatic axis/corneal astigmatic
axis is set to 1°.
1
5°
Display step of astigmatic axis/corneal astigmatic
axis is set to 5°.
Cyl Sign
+
Astigma sign is displayed with "+."
-
-
Astigma sign is displayed with "-."
MIX
Astigma sign is displayed with "MIX."
Topo-map
Smoothing
ON
Performs top-map smoothing.
OFF
OFF
Top-map smoothing is not done.
Summary Map
graph scale
0.1
Graph scale of summary map is set to 0.1.
1.0
0.2
Graph scale of summary map is set to 0.2.
0.5
Graph scale of summary map is set to 0.5.
1.0
Graph scale of summary map is set to 1.0.
2.0
Graph scale of summary map is set to 2.0.