6 Technical Information
6.1 Main unit specification
(1) Overview
Measuring principle
Microwave Pulse Echo
Operating frequency
5.8 GHz
Half-power beam width
Lengthwise
: 50 deg
Crosswise
: 23deg
Transmitting power
less than 35 µV/m at 3m
Measuring range
Max. 10 m (33’)
(2) Power
Supply voltage
16..36 VDC
(3) Output
Variable
Ullage / Level / Volume / Current /
Signal amplitude/Volume Max
Unit
Level, Ullage : m/ft
Volume : % Current : mA
Amplitude : dB
Signal type
Analog 4..20 mA, HART
Resolution
• Analog: 4 µA
• Digital: 1 mm (0.04")
Update time
1 s
Averaging time
1..120 s
Signal on alarm
Hold/Low(3.9mA)/High(22 mA)
6-1