84
―
HXPRM10mnCT002E
7.2.5 Digital Filter
Apply a digital filter to a process valuable to record the first order lag. From 99.5% response time
(T
Ⅰ
), the filter constant (K) is obtained by the following formula.
K=
Example)
When 99.5% response time is 50 second;
K= =0.0128
Set up the digital filter constant for Channel 2 to
“K = 0.0128”.
Enter the engineering mode (See the key operation
in page 78).
Use the
△
key to select
and press the
“
ENT
”
key.
Use the
△
key to alter a numerical value, or the
key to shift a digit. Press the
“
ENT
”
key.
Setting is completed. Returned to the channel
setting.
7.2.6 Settings Related to Recording
Sets a recording start/stop trigger, select tag/channel print, or set alarm print and logging print.
(1)
Recording start/stop trigger setting
Set whether the trigger of recording start/stop should be by the
“
RUN
”
key or DI.
Example)
When setting DI as the recording start/stop trigger
Enter the engineering mode (See the key operation
in page 78). Use the
△
key to indicate "
",
and press the
“
ENT
”
key.
Use the
△
key to select "
", and press the
“
ENT
”
key.
Use the
△
key to indicate "
", and press the
“
ENT
”
key.
Setting is completed. Returned to the Recording
Start/Stop Setting screen.
ENT
ENT
ENT
ENT
Display
Operation Keys
Description
[
Note
]
When indicates "
", RUN/STOP key does not operate.
Set “
to DI. See DI functions
in page 89
.
0.64
T
I
0.64
50
ENT
ENT
ENT
FEED
ENT
Display
Operation Keys
Description
ENT