127
―
HXPRM10mnCT002E
11.2.4 Standard Functions
Table 11.4
Standard Functions
Item
Description
Analog indication
None
Analog recording
Analog recording by the pen.
Engineering unit indication
None
Digital display
Indicates Channel No., Process variable data, Chart speed, Alarm setting
value on the display.
Logging print
Prints Date, Time, Chart speed, Process variable and Engineering unit at
a programmed interval. With the setting, it is possible for the
synchronous print/Asynchronous print to choose.
List print
Prints Chart speed, Sensor type, Measurement range, Engineering unit,
Alarm setting value, Comment, Printing description, Logging print
ON/OFF, Zone, Partial Compression/Expansion
Engineering list print
Prints Channel or Tag print, Alarm function, Logging print ON/OFF,
Reference time, Interval, Logging print Sync./ASync., Print gap correction
ON/OFF, Alarm hysteresis, Burn out, DI function (Option)
Manual print
Prints Measurement result by the key input.
Programming
Programs Chart speed, Alarm setting value, Logging, Date and Time.
Memory Back Up
A built-in lithium battery protects the clock function. The battery life is 10
years. (total power off period of the instrument : 5 years)A non-volatile
memory stores setting data and calibration data.
Alarm
Sets 2 types (H, L) of alarms per channel. Sets a total of 4 level.
Chart Speed
Selects Chart speed from 41 types.
Clock Indication
Indicates Year, Month, Day, Hour and Minute. Sets the year in A.D, and
adjusts leap year automatically.
Self Diagnostics
Occurring some type of the d
efect to indicate “E Err
**
”.
(
**
: type of the defect).
Scaling
Indicates and record the input of a unification signal etc. is changed into
the engineering scales.