55
―
HXPRM10mnCT002E
(2)
Current/Voltage
Thermocouple
Resistance Temperature Detector
)
Measurs Current, Voltage, Thermocouple and RTD.
Example)
When setting Thermocouple T for Channel 1(T : -100 to 300
℃
)
Hold down the MENU key for 3 seconds or more to
enter the setup mode. Indicates
, then,
press the
“
ENT
”
key.
Use the
△
key to select the channel you want to set.
Press the
“
ENT
“
key.
Use the
△
key to select the mode. Press the
“
ENT
“
key.
Use the
△
key to select the type. Press the
“
ENT
”
key.
Use the
△
key to select a sign and numeral.
Use the
key to shift a digit. Press the
“
ENT
”
key.
Use the
△
key to select a sign and numeral.
Use the key to shift a digit. Press the
“
ENT
”
key.
Press the
“
ENT
”
key. Setting is completed.
To return to the user mode, hold down the
“
MENU
”
key for 3 seconds or more.
[
Note
]
①
An entry of an incorrect numeral indicates an error,
or
.
Press the
“
ENT
”
key and re-enter a correct numeral.
②
For the range setting (When especially, don't change a decimal point position at the
thermocouple or in RTD) which doesn't have the necessity of the scaling, don't set a scaling.
Display
Operation Keys
Description
MENU
ESC
3 sec
ENT
ENT
ENT
ENT
FEED
ENT
FEED
ENT
ENT
(
Span setting
)
(
Zero setting
)