Use and Maintenance Handbook
– Prime 400 Packaging Machine
Page 67 of 71
12.3
Maintenance on the Pneumatic System
Below they are brought back detailed indications regarding the operation and the
operating way in order to solve eventuals anomalies in the components parts of
the pneumatic equipment.
12.3.1 Filter and pressure regulator
Anomaly
Probable Cause
Solutions
It isn’t possible to bring
down
the
pressure
value.
Lack
held
by
the
stopper
against
its
center
Take apart and clean
the valve seal-sealing
Change the component
It isn’t possible to obtain
the wanted pressure
value
Perforated membrane
Change the membran
Collapsed spring
Change the spring
Change the component
The outlet air flow from
the filter is insufficient
The filtering cartridge is
saturated
Clean or change the
filtering cartridge.
The condensation level
is too high
Clean the automatic
drain tank
Change the component
In the filter outlet can be
found
condensation
traces.
Diaphragm breakage
Change the diaphragm
Change the component