11.4.5
Bags length setup page
In this screen you can set the length of the bags (A), the length of the bag
correction value (B), the value (C) that indicates each number of bags takes place
the programmed cut. And the pause time value (from a welding and the other
one) in automatic cycle mode (D).
BAGS LENGTH SETTING PROCEDURE
The bags setting procedure i sas following:
- Set the length value of the bag (A);
- Set the correction value (B), expressed as percentage, in case of the bag is
longer or shorter than the value (A) (initial value = 100%);
- Produce a few bags and measure the actual length of the bag;
- If the bag is shorter than the set length, set a correction value higher than
100%, up to reach the correct desired length;
- If the bag is longer than the set length, set a correction value lower than
100%, up to reach the correct desired length.
A
C
D
B