Device Options
From the
Tools
menu, pick
General Settings
.
DSP Options
The DSP can be configured in case of a non-standard site installation. Select the
Tools/DSP Settings
menu entry or click on the DSP Settings button (
).
Figure 16: DSP-D300 Control300 DSP Settings
The Baud Rate and Polarity settings should not be modified unless told to do so
by Timewave support.
Sensitivity controls the amplitude detection for the decoding. This should be left
at 256. It may be increased or decreased for high-noise environments.
Half-Interspace Timing
Decrease packet update timing buffer
Allows packets to be closer together.
Allow Partial Packets
Allow incomplete packets – will be
filled out with NULLs
If a packet does not finish, transmit it
anyway.
Disable IFLOWS Error Correction
Allow Sliding Packet Recovery
Do not check for IFLOWS data
alignment on incoming bytes.
Allow Empty Packets
Allow NULL Bytes
Allow NULL data bytes.
IFLOWS Packet Test
Takes the final packet, decodes it, and
checks for data ranges.
47