Installation – Install the Tigo Access Point (TAP)
EI Residential Solar Solution Installation Manual |
23
Install the Tigo Access Point (TAP)
A TAP wirelessly communicates with TS4 devices to gather data and perform rapid shutdowns.
The TAP connects to the link via a T568B-scheme CAT5/6 cable.
Install the TAP centrally in an array for best coverage. Ensure there are no obstructions that
may interfere with the TAP signal to other TS4 units in the array. If the array has multiple roof
planes, you may need to install another TAP.
The TAP communicates directly with any TS4 within 10m. Each TS4 can relay data to and from
another TS4 within 10m. The TAP can communicate with any TS4 within 35m.
To install a TAP using a T568B-scheme CAT5/6 cable:
1.
Connect cable wires to the left side of the TAP using either the quick-connect or the
terminal block.
Use the right side terminals to connect a cable to another TAP. If there is only one TAP,
leave the terminating jumper in the right-side terminal block.