Installation, use and maintenance guide
COMPACT S22
–S26–S32 EVO5
Page
49
ENG
• Do not install the appliance with horizontal wall outlets only: Evacuation of products of combustion by natural draught must always
be guaranteed as well. Unsuitable installation of the outlets could cause a forced shut down of the appliance due to overpressure of
the exhaust smoke caused by a gust of wind.
• At the first startup, run the heater at the maximum power in a well-ventilated room, in order to dispose of the smoke generated by
the complete dryness and baking of the silicates contained in the enamel coating of the combustion chamber.
• Do not install a grill or outlet terminal that could slow down the flow of the combustion gases: this would obviously cause the
appliance to malfunction.
• Keep the appliance clean and check the burner as described in these instructions.
• Clean the smoke outlet regularly.
• Use good quality pellets: use of poor pellets can result in up to 50% less efficiency.
• The pellets must be stored in a well-ventilated, dry place.
• The generator door must always remain closed during normal operation.
• Do not touch hot outer surfaces, unless with special equipment.
• Do not pour the pellets directly into the brazier.
• Keep fuel and inflammable materials at a suitable distance.
• Use only original spare parts supplied by the manufacturer.