Installation, use and maintenance guide
COMPACT S22
–S26–S32 EVO5
Page
16
ENG
5.3 HYDRAULIC DIAGRAM WITH HEATING ONLY
Legenda
Key
A: andata impianto riscaldamento
A: heating system delivery
R: ritorno impianto riscaldamento
R: heating system return
S: saracinesca
S: gate valve
VNR: valvola di non ritorno
VNR: nonreturn valve
VEC: vaso di espansione chiuso per protezione
impianto
VEC: closed expansion tank for system protection
VM3VT: valvola miscelatrice punto fisso 55°C
VM3VT: mixing valve, fixed point 55°C
VSP: valvola saracinesca (da parzializzare in
funzione delle perdite di carico dell'impianto)
VSP: gate valve (throttle according to pressure
drop in the system)
APPARECCHIO
APPLIANCE
ATTENTION: it is mandatory to earth the generator. If this instruction is not observed serious damage, which
is not covered by warranty, will result to the body of the appliance. Have a skilled electrician check the
earthing. There must be no electric pote
ntial (Volt) between the generator earth and the system’s real earth
(earth plate). To prevent electrochemical corrosion of the appliance body do not use galvanised pipes and
fittings. Other materials must be earthed with special earthing cables in order to obtain a unipotential
earthing system.
R
S
A
S
VEC
VM3VT
A : andata impianto riscaldamento
R : ritorno impianto riscaldamento
S : saracinesca
VNR : valvola di non ritorno
VEC : vaso di espansione chiuso per protezione impianto
VM3VT : valvola miscelatrice punto fisso 55°C
VSP: valvola saracinesca (da parzializzare in funzione delle perdite di carico dell'impianto)
VSP
R
A
A
PP
A
RE
C
C
H
IO
VNR