Installation, use and maintenance guide
COMPACT S22
–S26–S32 EVO5
Page
22
ENG
THERMO ACS
Enables you to activate control of a boiler (if installed) for domestic hot water (ACS) assigning absolute
priority to the boiler requirements before replenishing the system.
This screen only appears if the
optional
sensor is connected to the appliance.
Display
The following information can appear on the display:
The appliance is in OFF phase.
1° MANUAL OPERATING POWER
2° MANUAL OPERATING POWER
3° MANUAL OPERATING POWER
4° MANUAL OPERATING POWER
5° MANUAL OPERATING POWER
In this mode the user can choose to run the appliance from the minimum power (therefore with the minimum pellet consumption) to
the maximum power (therefore with the maximum pellet consumption). In this case the appliance always runs at the set power
without any modulation in accordance with the target temperature.
AUTOMATIC LEVEL
The appliance modulates the operating power automatically based on the target temperature set by the user. (see para. 6.10).
Indicates the temperature of the domestic hot water boiler, if the optional sensor is connected.
Indicates the temperature of Sensor S1 for control of a puffer, if the optional sensor is connected.
Indicates the temperature of Sensor S2 for control of a puffer, if the optional sensor is connected.
Indicates that the circulation pump is activated when the water temperature in the boiler exceeds 61°C.
Indicates the boiler water temperature detected by the thermocouple.
The thermometer icon, on the left of the display, indicates the target temperature for the water in the boiler, which can be
adjusted by the user by means of the
Degrees Button.
Indicates that the appliance has been switched on by the contact of an external chronothermostat.
Indicates that the appliance has been connected to a puffer which is requesting heat.
Indicates that the ON/OFF programming set through CHRONO has been enabled
Indicates the room temperature detected by the thermocouple, if connected.
The thermometer icon, on the right of the display, indicates the target room temperature set by the user if the optional
sensor is connected