TK 56704-1-OP-EN
95
Fuse
Size
Function
F10
10A
8X Power (Install fuse in right position)
F11
None
No Fuse
F12
5A
2A Power to CAN Connector J13
F13
2A
8FC Circuit (Remote Status Light/Optional
Power)
F20
2A
Alternator Sense
F21
60A
Main Fuse (2 Circuit)
F25
7.5A
HPCO Switch Circuit
F26
5A
Power to CAN Connector J98
F10
When fuse F10 is installed in the right position the On/Off keys on the HMI turn the unit
on and off. When fuse F10 is installed in the left position the unit will start and run without
the HMI controller.
Electric Standby Specifications (SmartPower™
Model 50 Units)
Electric Motor and Overload Relay
T-1090 and T-1090 SPECTRUM
Voltage/
Phase/
Frequency
Horse-
power
Kilowatts
RPM
Full Load
(amps)
Overload
Relay
Setting
(amps)
230/3/50
10.0
7.5
1460
25.3
38
200-230/3/60
12.0
8.9
1750
28.8
38
400/3/50
10.0
7.5
1460
13.90
19
460/3/60
12.0
8.9
1750
14.4
19
Summary of Contents for T-1090 SPECTRUM