ntt:: HIGH SPEED LOCKOUT TIMEOUT: If High Speed Lockout Mode
is selected, the High Speed Inhibit Timeout feature may be set to
return the unit to normal operation after a set time period has
expired. This prevents extended operation with high speed
operation locked out. The time period may be from 15 minutes to
2 hours. If the time period is set and is exceeded, the unit will
return to normal operation, with high speed operation allowed. If
this occurs, the message HIGH SPEED LOCKOUT ACTIVE at the
top of the display will disappear. If necessary to return to High
Speed Lockout Mode, press the High Speed Lockout Key again.
The High Speed Lockout Key is a toggle. If high speed is currently allowed,
pressing the High Speed Lockout Key will disable high speed operation.
Pressing the High Speed Lockout Key again will allow high speed operation.
To change the setting, press the High Speed Lockout key as shown (
).
Figure 44.
High Speed Lockout Key
The display will briefly show [PROGRAMMING HIGH SPEED LOCKOUT -
PLEASE WAIT].
Figure 45.
Programming Screen