42
TK 56704-1-OP-EN
Figure 42.
Defrost Started
The display then shows the Defrost display. The bar indicator shows
approximately the percentage of time remaining to complete the defrost
cycle. The bar indicator (
) shows that the Zone 1 defrost cycle
is approximately 25% complete.
Figure 43.
Defrost Display
Terminating a Defrost Cycle
The defrost cycle terminates automatically when the coil temperature is
greater than or equal to 52°F (11°C) or the defrost timer expires. Defrost can
also be terminated by turning the unit off and back on.
Selecting High Speed Lockout Mode (If Enabled)
High speed operation can be locked out in noise sensitive areas if required.
N
No
otte
e:: High Speed Lockout Enable must be set to [Enabled] in the Guarded
Access/Programmable Features Menu or this feature will not be
available.